Assessment of Feldkamp-Davis-Kress Reconstruction Parameters in Overall Image Quality in Cone Beam Computed Tomography

Author:

Kim Hajin1,Choi Jun-Seon2ORCID,Lee Youngjin3

Affiliation:

1. Department of Health Science, General Graduate School of Gachon University, 191, Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

2. Department of Dental Hygiene, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea

3. Department of Radiological Science, Gachon University, 191, Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

Abstract

In low-dose cone beam computed tomography (CT), the insufficient number of photons inevitably results in noise, which reduces the accuracy of disease diagnosis. One approach to improving the image quality of CT images acquired using a low-dose protocol involves the utilization of a reconstruction algorithm that efficiently reduces noise. In this study, we modeled the Feldkamp–Davis–Kress (FDK) algorithm using various filters and projection angles and applied it to the reconstruction process using CT simulation. To quantitatively evaluate the quality of the reconstruction images, we measured the coefficient of variation (COV), and signal-to-noise ratio (SNR) in the air, brain, and bone regions to evaluate the noise level. Furthermore, we calculated root mean square error (RMSE), universal image quality index (UQI), and blind/referenceless image spatial quality evaluator (BRISQUE) as similarity and no-reference evaluation. The Hann filter of the FDK algorithm showed superior performance in terms of COV, SNR, RMSE, and UQI compared to the other filters. In addition, when analyzing the COV and SNR results, we observed that image quality increased significantly at projection angles smaller than approximately 2.8°. Moreover, based on BRISQUE results, we confirm that the Shepp–Logan filter exhibited the most superior performance. In conclusion, we believe that the application of the Hann filter in the FDK reconstruction process offers significant advantages in improving the image quality acquired under a low-dose protocol, and we expect that our study will be a preliminary study of no-reference evaluation of CT reconstruction images.

Funder

National Foundation of Korea (NRF) funded by the Korean government

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3