ANN-Based Discernment of Septic and Inflammatory Synovial Fluid: A Novel Method Using Viscosity Data from a QCR Sensor

Author:

Miranda-Martínez AndrésORCID,Sufrate-Vergara BertaORCID,Fernández-Puntero Belén,Alcaide-Martin María JoséORCID,Buño-Soto AntonioORCID,Serrano-Olmedo José JavierORCID

Abstract

The synovial fluid (SF) analysis involves a series of chemical and physical studies that allow opportune diagnosing of septic, inflammatory, non-inflammatory, and other pathologies in joints. Among the variety of analyses to be performed on the synovial fluid, the study of viscosity can help distinguish between these conditions, since this property is affected in pathological cases. The problem with viscosity measurement is that it usually requires a large sample volume, or the necessary instrumentation is bulky and expensive. This study compares the viscosity of normal synovial fluid samples with samples with infectious and inflammatory pathologies and classifies them using an ANN (Artificial Neural Network). For this purpose, a low-cost, portable QCR-based sensor (10 MHz) was used to measure the viscous responses of the samples by obtaining three parameters: Δf, ΔΓ (parameters associated with the viscoelastic properties of the fluid), and viscosity calculation. These values were used to train the algorithm. Different versions of the ANN were compared, along with other models, such as SVM and random forest. Thirty-three samples of SF were analyzed. Our study suggests that the viscosity characterized by our sensor can help distinguish infectious synovial fluid, and that implementation of ANN improves the accuracy of synovial fluid classification.

Funder

Consejo Nacional de Ciencia y Tecnología

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference44 articles.

1. Mundt, A.L., and Shanahan, K. (2010). Graff’s Textbook of Routine Urinalysis and Body Fluids, Lippincott Williams & Wilkins. Print book: English.

2. Synovial fluid;Damiano;EMC-Rhumatologie-Orthopedie,2004

3. Synovial fluid analysis;Brannan;J. Emerg. Med.,2006

4. Synovial fluid analysis;Cabiedes;Reumatología Clínica (Engl. Ed.),2010

5. Studies on the concentration and intrinsic viscosity of hyaluronic acid in synovial fluids of patients with rheumatic diseases;Stafford;Ann. Rheum. Dis.,1964