Heat Transfer Characteristics of Cold Water Phase-Change Heat Exchangers under Active Icing Conditions

Author:

Liu ChangqingORCID,Wu RonghuaORCID,Yu Hao,Zhan Hao,Xu Long

Abstract

Under active icing conditions, the heat transfer performance of the CPHE has a significant impact on the system’s efficiency and energy consumption. Using the enthalpy-porosity method for describing the solidification process of liquids, the simulation and analysis of the effects of different parameter changes on the CPHE heat transfer performance were conducted to clarify the effects of the changes in the intermediary side inlet water temperature, intermediate water flow rate, and cold water flow rate on the heat transfer process in the CPHE. According to our results, changing the intermediary inlet water temperature has a greater impact on the heat transfer process in the cold-water phase-change heat exchangers. For every decrease of 0.5 °C in the intermediary side inlet water temperature, the average heat transfer coefficient increases by approximately 50 W/m2-K. Changes in the intermediary water flow rate affect the cold water phase-change heat exchanger’s heat transfer process. By increasing the intermediary water flow rate, the average heat transfer coefficient of a cold water phase-change heat exchanger can be improved, but the growth decreases, and the maximum flow rate of the intermediary water should not exceed 0.5 m per second. A change in the cold water flow rate in the cold water phase-change heat exchanger’s heat transfer process has a small impact on the cold water flow rate, increasing by 0.02 m/s each, with the average heat transfer coefficient increasing by 20 W/m2-K.

Funder

Demonstration of low-grade energy heating and cooling technology and its application

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference24 articles.

1. Heat pumps and our low-carbon future: A comprehensive review

2. Techno-economic control strategy optimization for water-source heat pump coupled with ice storage district cooling system

3. Research and development of photovoltaic air source heat p-ump;Xu;J. Sol. Energy,2022

4. Simulation study on sand erosion and wear of air source heat pump heat exchange;Ma;Fluid Mach.,2021

5. Experimental study on closed cooling tower ground source heat pump system in summer;Li;Fluid Mach.,2019

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3