Energy Saving Evaluation with Low Liquid to Gas Ratio Operation in HVAC&R System

Author:

Ha Ju-wanORCID,Kim Yu-jinORCID,Park Kyung-soonORCID,Song Young-hakORCID

Abstract

Previous studies have been conducted by employing various methods to reduce the condenser water temperature, a crucial control variable to consider when attempting to improve the operational efficiency of a chiller. The existing literature dealing with the effects of low-condenser water temperatures is limited, as the cooling water flow rate is often considered the operating variable of the condenser loop. However, to produce additional low condenser water temperatures, the approach temperature of the cooling tower in the system must be reduced. To reduce the approach temperature, it is necessary to review the physical behavior and efficiency of the cooling tower according to the change in the liquid to gas ratio (LGR), which is dependent upon the condenser water flow rate and the cooling tower fan air flow rate within the condenser loop. However, this process has rarely been reviewed in previous studies. Therefore, this study developed a new cooling tower control algorithm from the LGR perspective, and the operational effectiveness was quantitatively reviewed using EnergyPlus. Compared to the conventional conditions, when the cooling tower operation algorithm for low-approach temperatures was applied, the annual energy saving was 27.0%, the average chiller COP was improved by 27.8%, and the average system COP was improved by 47.4%. Furthermore, even when the algorithm was not applied at the same condenser water set temperature, the annual energy saving was 15%. The average COP of the chiller and COP of the system is improved by 2% and 23.2%, respectively. These results indicated that when a cooling tower is operated with a low LGR, even under the same outdoor air and load conditions, the cooling system’s efficiency can be improved with a change in the control algorithm without installing additional high-efficiency equipment.

Funder

Korea Health Industry Development Institute

Ministry of Health & Welfare, Republic of Korea

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference65 articles.

1. The Future of Cooling: Opportunities for Energy-Efficient Air Conditioninghttps://www.iea.org/reports/the-future-of-cooling

2. Saving water with cooling towers;Morrison;ASHRAE J.,2015

3. Improved cooling tower control of legacy chiller plants by optimizing the condenser water set point

4. Improved model and optimization for the energy performance of chiller system with diverse component staging

5. A practical approach to chiller plants’ optimisation