Abstract
This paper presents the results of PIV measurements of turbulent airflow in a channel with a single ribbed wall. The rough elements had the form of evenly spaced trapezoids. The ratio of the height of a single rib to the height of the measurement channel was 0.1. The ratio of the distance between adjacent ribs to the height of a single rib (i.e., the w/k ratio) was 5, which suggests a transitional region within the airflow structure between the d- and k- types. The measurements were carried out for the inlet velocity, at which the Reynolds number (Re) was equal to 32,500. The distance to the first rib, at which the turbulent velocity profile is fully developed, was determined. The distribution of the average velocity components, the velocity fluctuation components, turbulent shear stress, as well as the turbulence kinetic energy between two adjacent ribs was presented. The analysis of average streamlines indicated the existence of two vortex structures between the ribs.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献