Abstract
Magnetic flux leakage (MFL) detection is a common nondestructive detection method which is usually used to detect the surface defects of steel pipes and rails. To suppress the interference of lift-off on the detection signal of the defects in rail head surfaces, a filtering method is proposed according to the distribution characteristics of the defect leakage magnetic field (LMF) in different directions. The sensor array is used to confirm the reference signal according to the difference between the signals in x and z directions. The installation mode of the sensors is deduced according to the distribution of the defect LMF. The experimental results show that this method can effectively suppress the lift-off interference in the MFL signal of the defects in the rail head surfaces.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference22 articles.
1. Review of rail defect non-destructive testing and evaluation;Zhang;Chin. J. Sci. Instrum.,2019
2. Rail Flaw Detection Technologies for Safer, Reliable Transportation: A Review
3. Experiment research on switch rail defect monitoring using ultrasonic guided waves;Fu;Railway Engineering,2018
4. Phased array ultrasonic testing methods for welds in bogie frames of railway vehicles
5. Eddy current testing and evaluation method for fine cracks on rail surface;Hu;Equip. Manag. Maint.,2021
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献