Fabrication of a PLA/PVA-BIO-HA Polymeric Membrane by the Electrospinning Technique
Author:
Arroyo-Reyes Brenda Lizbeth1, Gómez-Muñoz Celia Lizeth2, Zaca-Morán Placido2ORCID, Galindo-Ramírez Fabián1, Morales-Sánchez Marco Antonio3ORCID
Affiliation:
1. Instituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla C.P. 72570, Mexico 2. Instituto de Ciencias, Benemérita Universidad Autónoma de Puebla, Puebla C.P. 72050, Mexico 3. Facultad de Ingeniería Química, Benemérita Universidad Autónoma de Puebla, Puebla C.P. 72570, Mexico
Abstract
In the present work, the fabrication of a membrane composed of polylactic acid (PLA), polyvinyl alcohol (PVA), and Biological Hydroxyapatite (BIO-HA) is reported using the coaxial electrospinning technique. The membrane fabrication process involved mixing a solution of PLA and trichloromethane (TCM) with a second solution of PVA, isopropyl alcohol (IPA), distilled water, and BIO-HA at 110 °C. Subsequently, the electrospinning process was carried out using a voltage of 25 kV for 30 min on a rotating drum collector at 1000 rpm. The membrane was characterized through Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray spectroscopy (EDS), Fourier-Transform Infrared spectroscopy (FTIR), Thermogravimetric Analysis (TGA), and Differential Scanning Calorimetry (DSC). The morphological results revealed the presence of randomly arranged fibers with an average diameter of 290 ± 9 nm and interfiber spacing ranging from 200 to 700 nm, which are characteristics conducive to cell proliferation. Additionally, FTIR studies confirmed the presence of BIO-HA and the constituent elements of the polymers in the composite membrane. The polymeric membrane in contact with human mesenchymal stem cells was characterized as showing significant differences in its behavior at 6, 24, and 72 h post-contact. These studies indicate that the membrane provides physical support as a scaffold due to its suitable morphology for cell adhesion and proliferation, attributable to the electrospinning conditions as well as the polymers contained in BIO-HA. Membrane toxicity was confirmed through a cytotoxicity study using fluorescence microscopy, which showed that the membrane provided a favorable environment for cell proliferation. These results suggest that exposure to BIO-HA enhances its potential application in bone and joint tissue regeneration.
Reference43 articles.
1. “Hard” ceramics for “Soft” tissue engineering: Paradox or opportunity?;Kargozar;Acta Biomater.,2020 2. New perspectives: In-situ tissue engineering for bone repair scaffold;Cao;Compos. Part B Eng.,2020 3. Manzini, B.M., Machado, L.M.R., Noritomi, P.Y., and da Silva, J.V.L. (2021). Advances in Bone tissue engineering: A fundamental review. J. Biosci., 46. 4. Biopolymers for tissue engineering applications: A review;Biswal;Mater. Today Proc.,2021 5. Mazzoni, E., Iaquinta, M.R., Lanzillotti, C., Mazziotta, C., Maritati, M., Montesi, M., Sprio, S., Tampieri, A., Tognon, M., and Martini, F. (2021). Bioactive materials for soft tissue repair. Front. Bioeng. Biotechnol., 9.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|