Abstract
Adverse effects of wastewater on the hygiene of human and circumstances is a major issue in society. Appropriate refining systems with high efficiency is required to treat the wastewater. Sewage treatment plant plays a major and important role in conserving incredible nature of the environment. Microbiologically Induced Corrosion (MIC) is an important phenomenon in sewage structures which causes the deterioration of infrastructures. Huge capital has been spent and efforts have been made on wastewater treatment infrastructure to increase operating efficiency and reliability of compliance. The investments in reimbursement and maintenance of sewer structures upsurge with an increase in the rate of MIC. The focus of this review is to describe MIC in sewer structure and the factors influencing the corrosion such as the generation of Sulfuric acid (H2SO4), Relative Humidity (RH), pH of the concrete structure and temperature. Modern developments in the design of Fiber Optical Sensors (FOSs) for observing the parameters including pH, Hydrogen Sulfide (H2S), RH and temperature will be discussed.
Subject
Physical and Theoretical Chemistry,Analytical Chemistry