Influence of Silsesquioxane-Containing Ultra-Thin Polymer Films on Metal Oxide Gas Sensor Performance for the Tunable Detection of Biomarkers
-
Published:2024-05-05
Issue:5
Volume:12
Page:76
-
ISSN:2227-9040
-
Container-title:Chemosensors
-
language:en
-
Short-container-title:Chemosensors
Author:
Lupan Oleg1234, Brinza Mihai3ORCID, Piehl Julia1, Ababii Nicolai3ORCID, Magariu Nicolae3ORCID, Zimoch Lukas2, Strunskus Thomas1ORCID, Pauporte Thierry4ORCID, Adelung Rainer2ORCID, Faupel Franz1ORCID, Schröder Stefan1ORCID
Affiliation:
1. Chair for Multicomponent Materials, Department of Materials Science, Kiel University, Kaiserstraße 2, D-24143 Kiel, Germany 2. Functional Nanomaterials, Faculty of Engineering, Institute for Materials Science, Kiel University, Kaiserstraße 2, D-24143 Kiel, Germany 3. Center for Nanotechnology and Nanosensors, Department of Microelectronics and Biomedical Engineering, Technical University of Moldova, 168 Stefan cel Mare Av., MD-2004 Chisinau, Moldova 4. Institut de Recherche de Chimie Paris-IRCP, Chimie ParisTech, PSL Université, rue Pierre et Marie Curie 11, 75231 Paris, CEDEX 05, France
Abstract
Certain biomarkers in exhaled breath are indicators of diseases in the human body. The non-invasive detection of such biomarkers in human breath increases the demand for simple and cost-effective gas sensors to replace state-of-the-art gas chromatography (GC) machines. The use of metal oxide (MOX) gas sensors based on thin-film structures solves the current limitations of breath detectors. However, the response at high humidity levels, i.e., in the case of exhaled human breath, significantly decreases the sensitivity of MOX sensors, making it difficult to detect small traces of biomarkers. We have introduced, in previous work, the concept of a hybrid gas sensor, in which thin-film-based MOX gas sensors are combined with an ultra-thin (20–30 nm) polymer top layer deposited by solvent-free initiated chemical vapor deposition (iCVD). The hydrophobic top layer enables sensor measurement in high-humidity conditions as well as the precise tuning of selectivity and sensitivity. In this paper, we present a way to increase the hydrogen (H2) sensitivity of hybrid sensors through chemical modification of the polymer top layer. A poly(1,3,5,7-tetramethyl-tetravinylcyclotetrasiloxane) (PV4D4) thin film, already applied in one of our previous studies, is transformed into a silsesquioxane-containing top layer by a simple heating step. The transformation results in a significant increase in the gas response for H2 ~709% at an operating temperature of 350 °C, which we investigate based on the underlying sensing mechanism. These results reveal new pathways in the biomedical application field for the analysis of exhaled breath, where H2 indicates gastrointestinal diseases.
Funder
German Research Foundation State Program LIFETECH SulfurSilicon Batteries (SuSiBaBy) Project of the EUSH and EFRE
Reference51 articles.
1. Pathak, A.K., Swargiary, K., Kongsawang, N., Jitpratak, P., Ajchareeyasoontorn, N., Udomkittivorakul, J., and Viphavakit, C. (2023). Recent Advances in Sensing Materials Targeting Clinical Volatile Organic Compound (VOC) Biomarkers: A Review. Biosensors, 13. 2. Application of Metal-Organic Frameworks for Sensing of VOCs and Other Volatile Biomarkers;Hajivand;Coord. Chem. Rev.,2024 3. Roles of Inflammatory Biomarkers in Exhaled Breath Condensates in Respiratory Clinical Fields;Choi;Tuberc. Respir. Dis.,2024 4. Brinza, M., Schröder, S., Ababii, N., Gronenberg, M., Strunskus, T., Pauporte, T., Adelung, R., Faupel, F., and Lupan, O. (2023). Two-in-One Sensor Based on PV4D4-Coated TiO2 Films for Food Spoilage Detection and as a Breath Marker for Several Diseases. Biosensors, 13. 5. Gas Sensors Based on Co3O4/TiO2 Core-Shell Nanofibers Prepared by Coaxial Electrospinning for Breath Marker Acetone Detection;Fu;Ceram. Int.,2024
|
|