Abstract
An electrochemical sensor was fabricated for the rapid and simple detection of enrofloxacin (EF). Modification of screen-printed gold electrodes (SPE) with molecularly imprinted polymers (MIPs) allowed the detection of enrofloxacin by square wave voltammetry (SWV), measuring the oxidation peak at +0.9 V. The detection principle of molecularly imprinted polymers (MIPs) is based on the formation of binding sites with affinities and specificities comparable with those of natural antibodies. The detection of enrofloxacin showed a linear range of 0.01–0.1 mM with a detection limit LOD of 0.02 mM. The development of a non-imprinted polymer (NIP) control sensor allowed for better and more efficient detection. In addition, the sensor is portable, having the advantage of analyzing and detecting molecules of interest without the need to take the sample to a laboratory.
Subject
Physical and Theoretical Chemistry,Analytical Chemistry
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献