Design of a Portable and Reliable Fluorimeter with High Sensitivity for Molecule Trace Analysis

Author:

López-Pérez Germán1ORCID,González-Arjona Domingo1,Roldán González Emilio1,Román-Hidalgo Cristina2ORCID

Affiliation:

1. Department of Physical Chemistry, Faculty of Chemistry, University of Sevilla, C/Prof. García González 1, E-41012 Sevilla, Spain

2. Department of Analytical Chemistry, Faculty of Chemistry, University of Sevilla, C/Prof. García González 1, E-41012 Sevilla, Spain

Abstract

There is a growing need for portable, highly sensitive measuring equipment to analyze samples in situ and in real time. For these reasons, it is becoming increasingly important to research new experimental equipment to carry out this work with advanced, robust and low-cost devices. In this framework, a flexible, portable and low-cost fluorimeter (under EUR 500), based on a C12880 MA MEMS micro-spectrometer with an Arduino compatible breakout board, has been developed for the trace analysis of biological substances. The proposed system can employ two selectable excitation sources for flexibility, one in the visible region at 405 nm (incorporated in the board) and an external LED at 365 nm in the UV region. This additional excitation source can be easily interchanged, varying the LED type for investigating any fluorophore compound of interest. The measurement process is micro-controlled, which allows the precise control of the spectrometer sensitivity by adjusting the integration time of each experiment separately. Data acquisition is easy, reliable and interfaced with a spreadsheet for fast spectra visualization and calculations. For testing the performance of the new device in fluorescence measurements, different fluorophore molecules which can be commonly found in biological samples, such as Fluorescein, Riboflavin, Quinine, Rhodamine b and Ru (II)-bipyridyl, have been employed. A high sensitivity and low quantitation limits (in the ppb range) have been found in all cases for the investigated chemicals. The portable device is also suitable for the study of other interesting phenomena, such as fluorescence quenching induced by chemical agents (such as halide anions or even auto-quenching). In this sense, an application for the quantification of chloride anions in aqueous solutions has been performed obtaining a LOD value of 18 ppm. The obtained results for all chemicals investigated with the proposed fluorimeter are always very similar in quantification figures, or even better than the data reported in literature, when using commercial laboratory equipment.

Funder

Junta de Andalucía

Universidad de Sevilla

Publisher

MDPI AG

Subject

Physical and Theoretical Chemistry,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3