Abstract
In this study a variety of novel symmetrically and asymmetrically functionalized pillar[5]arenes were synthesized, structurally characterized and applied as ionophores in PVC-plasticized membrane potentiometric sensors. During the sensitivity studies it was found that these novel sensors demonstrate pronounced cationic response towards different metal ions in aqueous solutions. A selectivity evaluation revealed that the developed sensors do not possess sharp preferences to particular ions, but offer a broad cross-sensitivity and can be employed in potentiometric multisensor systems.
Subject
Physical and Theoretical Chemistry,Analytical Chemistry
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献