Abstract

Solar energy is a sustainable and environmentally safe power source due to its widespread availability and cleanliness. Nowadays, the grid-integrated solar photovoltaic system (SPVS) has to work with a polluted grid, an imbalanced load, and changing solar irradiation. When the grid is polluted, it is also crucial to enhance power quality (PQ) at a common coupling point (CCP) while supplying significantly distorted and unreliable loads. For effective synchronization and the production of unit templates, it is necessary to retrieve positive sequence components (PSCs) from distorted/imbalanced grid voltages. In this study, a control algorithm for a grid-integrated SPVS is developed using a multi-variable filter dual-enhanced adaptive notch filter phase-locked loop (MVF-DEANF-PLL) which offers seamless grid synchronization and PQ issue alleviation. In a polluted grid environment, the proposed control approach aids in the reduction in current/voltage harmonics, DC offset, unity power factor (UPF) operation, and rapid estimation of sequence components. Even in unbalanced grid conditions, the proposed control approach efficiently extracts PSCs of both unbalanced load current and polluted CCP grid voltages. These PSCs are utilized to generate unit templates and reference source currents. By using a flexible step-size incremental conductance (FSSINC) maximum power point tracking (MPPT) technique, the highest available power of SPVS is gathered. MATLAB/Simulink is utilized for modelling a 7.22 kW SPV system, and results from simulations which depict that the proposed algorithm efficiently resolves PQ concerns in distribution networks with a polluted grid. Test observations of a 1 kW laboratory-developed SPVS prototype were recorded in compliance with the IEEE-519 standard. The suggested control technique complies with the aforementioned standards by providing a sinusoidal balanced source current that has a THD of 2.5%. Comparisons between the proposed control’s performance and that of a conventional SRF-PLL-based control technique were also performed.

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3