Abstract
The constant phase element (CPE) is found in most battery and supercapacitor equivalent circuit models proposed to interpret data in the frequency domain. When these models are used in the time domain, the initial conditions in the fractional differential equations must be correctly imposed. The initial state problem remains controversial and has been analyzed by various authors in the last two decades. This article attempts to clarify this problem by proposing a procedure to prepare the initial state and defining a decay function that reveals the effect of the initial state in several illustrative examples. This decay function depends on the previous history, which is reflected in the time needed to prepare the initial state and on the current profile assumed for this purpose. This effect of the initial state is difficult to separate and can lead to the misinterpretation of the CPE parameter values.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献