Abstract
In the context of the increased acceptance and usage of EV, V2B has proven to be a new and promising use case. Although this topic is already being discussed in literature, there is still a lack of experience on how such a system, of allowing bidirectional power flows between an EV and building, will work in a residential environment. The challenge is to optimize the interplay of electrical load, PV generation, EV, and optionally a HES. In total, fourteen different scenarios are explored for a German household. A two-step approach is used, which combines a computationally efficient linear optimizer with a detailed modelling of the non-linear effects on the battery. The change in battery degradation, storage system efficiency, and OPEX as a result of different, unidirectional and bidirectional, EV charging schemes is examined for both an EV battery and a HES. The simulations show that optimizing unidirectional charging can improve the OPEX by 15%. The addition of V2B leads to a further 11% cost reduction, however, this corresponds with a 12% decrease in EV battery lifetime. Techno-economic analysis reveals that the V2B charging solution with no HES leads to strong self-consumption improvements (EUR 1381 savings over ten years), whereas, this charging scheme would not be justified for a residential prosumer with a HES (only EUR 160 savings).
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
20 articles.