Fetlock Joint Angle Pattern and Range of Motion Quantification Using Two Synchronized Wearable Inertial Sensors per Limb in Sound Horses and Horses with Single Limb Naturally Occurring Lameness

Author:

Pagliara EleonoraORCID,Marenchino MaddalenaORCID,Antenucci Laura,Costantini Mario,Zoppi GiacomoORCID,Giacobini Mario Dante LucioORCID,Bullone Michela,Riccio Barbara,Bertuglia AndreaORCID

Abstract

Fetlock joint angle (FJA) pattern is a sensitive indicator of lameness. The first aim of this study is to describe a network of inertial measurement units system (IMUs) for quantifying FJA simultaneously in all limbs. The second aim is to evaluate the accuracy of IMUs for quantifying the sagittal plane FJA overground in comparison to bi-dimensional (2-D) optical motion capture (OMC). 14 horses (7 free from lameness and 7 lame) were enrolled and analyzed with both systems at walk and trot on a firm surface. All enrolled horses were instrumented with 8 IMUs (a pair for each limb) positioned at the dorsal aspect of the metacarpal/metatarsal bone and pastern and acquiring data at 200 Hz. Passive markers were glued on the center of rotation of carpus/tarsus, fetlock, and distal interphalangeal joint, and video footages were captured at 60 Hz and digitalized for OMC acquisition. The IMU system accuracy was reported as Root Mean Square Error (RMSE) and Pearson Correlation Coefficient (PCC). The Granger Causality Test (GCT) and the Bland–Altman analysis were computed between the IMUs and OMC patterns to determine the agreement between the two systems. The proposed IMU system was able to provide FJAs in all limbs using a patented method for sensor calibration and related algorithms. Fetlock joint range of motion (FJROM) variability of three consecutive strides was analyzed in the population through 3-way ANOVA. FJA patterns quantified by IMUs demonstrated high accuracy at the walk (RMSE 8.23° ± 3.74°; PCC 0.95 ± 0.03) and trot (RMSE 9.44° ± 3.96°; PCC 0.96 ± 0.02) on both sound (RMSE 7.91° ± 3.19°; PCC 0.97 ± 0.03) and lame horses (RMSE 9.78° ± 4.33°; PCC 0.95 ± 0.03). The two systems’ measurements agreed (mean bias around 0) and produced patterns that were in temporal agreement in 97.33% of the cases (p < 0.01). The main source of variability between left and right FJROM in the population was the presence of lameness (p < 0.0001) and accounted for 28.46% of this total variation. IMUs system accurately quantified sagittal plane FJA at walk and trot in both sound and lame horses.

Publisher

MDPI AG

Subject

General Veterinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3