Ultrasonic Measurement of Axial Preload in High-Frequency Nickel-Based Superalloy Smart Bolt

Author:

Liu Shuang,Sun Zhongrui,Ren Guanpin,Liao Cheng,He Xulin,Luo Kun,Li Ru,Jiang Wei,Zhan Huan

Abstract

A high-frequency, piezoelectric thin-film sensor was successfully deposited on a nickel-based superalloy bolt by radio frequency magnetron sputtering to develop a smart, nickel-based superalloy bolt. Ultrasonic response characterization, high accuracy, and repeatability of ultrasonic measurement of axial preload in nickel-based superalloy smart bolts are reported here and were fully demonstrated. The axial preload in the nickel-based superalloy smart bolt was directly measured by the bi-wave method (TOF ratio between transverse and longitudinal-mode waves) without using the traditional integration of a longitudinal and shear transducer. A model concerning the bolt before and after tensioning was established to demonstrate the propagation and displacement distribution of the ultrasonic waves inside a nickel-based superalloy smart bolt. The measured A-scan signal presented significantly favorable features including a mixture of transverse and longitudinal mode waves, a pure and broad frequency spectrum which peaked at 17.14 MHz, and high measurement accuracy below 3% for tension of 4 kN–20 kN. For the temporal ultrasonic signal, the measurement envelopes were narrower than for the counterpart of the simulation, justifying the ‘filtration’ advantage of the high-frequency sensor. Both the TOF change of the single longitudinal-mode wave and the TOF ratio between transverse- and longitudinal-mode waves increased linearly with preload force in the range of 0 kN to 20 kN. Compared with the commercial piezoelectric probe, the proposed probe, based on the combination of a high-frequency, piezoelectric thin-film sensor and a magnetically mounted transducer connector, exhibited high tolerance to temperatures as high as 320 °C and high repeatability free from some interference factors such as bolt detection position change and couplant layer thickness. The results indicate that this system is a promising axial preload measurement system for high-temperature fasteners and connectors, and the proposed sensor is a practical, high-frequency ultrasonic sensor for non-destructive testing.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3