Air-Side Nusselt Numbers and Friction Factor’s Individual Correlations of Finned Heat Exchangers

Author:

Marcinkowski MateuszORCID,Taler Dawid,Taler Jan,Węglarz Katarzyna

Abstract

Currently, when designing finned heat exchangers (FHE), the average value of the entire heat transfer coefficient (HTC) is considered. However, each row of the heat exchanger (HEX) has different hydraulic-thermal characteristics. The novelty of this research is to present the differentiation of the individual air-side Nusselt number and Darcy-Weisbach friction factor correlations in each row of FHE using CFD modelling. FHE has four-rows, circular tubes, and continuous fins with a staggered tube arrangement. Relationships for the Nusselt number and D-W friction factor derived for the entire exchanger based on CFD modelling were compared with those available in the literature, determined using experimental data. The maximum relative differences between the Nusselt number for a four-row FHE determined experimentally and by CFD modelling are in the range from 22% for a Reynolds number based on a tube outside diameter of 1000 to 30% for a Reynolds number of 13,000. The maximum relative differences between the D-W friction factor for a four-row FHE determined experimentally and by CFD modelling are in the range of 50% for a Reynolds number based on a tube outer diameter of 1000 to 10% for a Reynolds number of 13,000. The CFD modelling performed shows that in the range of Reynolds numbers based on hydraulic diameters from 150 to 1400, the Nusselt number for the first row in a four-row FHE is about 22% to 15% higher than the average Nusselt number for the entire exchanger. In the range of Reynolds number changes based on hydraulic diameter from 2800 to 6000, the Nusselt numbers on the first and second rows of tubes are close to each other. Correlations of Nusselt numbers and D-W friction factors derived for individual tube rows can be used in the design of plate-fin and tube heat exchangers used in equipment such as air-source heat pumps, automotive radiators, air-conditioning systems, and in air hot-liquid coolers. In particular, the correlations can be used to select the optimum number of tube rows in the exchanger.

Funder

National Centre for Research and Development

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3