Abstract
This study establishes typical Diagnostic Reference Levels (DRL) values and assesses patient doses in computed tomography (CT)-guided biopsy procedures. The Effective Dose (ED), Entrance Skin Dose (ESD), and Size-Specific Dose Estimate (SSDE) were calculated using the relevant literature-derived conversion factors. A retrospective analysis of 226 CT-guided biopsies across five categories (Iliac bone, liver, lung, mediastinum, and para-aortic lymph nodes) was conducted. Typical DRL values were computed as median distributions, following guidelines from the International Commission on Radiological Protection (ICRP) Publication 135. DRLs for helical mode CT acquisitions were set at 9.7 mGy for Iliac bone, 8.9 mGy for liver, 8.8 mGy for lung, 7.9 mGy for mediastinal mass, and 9 mGy for para-aortic lymph nodes biopsies. In contrast, DRLs for biopsy acquisitions were 7.3 mGy, 7.7 mGy, 5.6 mGy, 5.6 mGy, and 7.4 mGy, respectively. Median SSDE values varied from 7.6 mGy to 10 mGy for biopsy acquisitions and from 11.3 mGy to 12.6 mGy for helical scans. Median ED values ranged from 1.6 mSv to 5.7 mSv for biopsy scans and from 3.9 mSv to 9.3 mSv for helical scans. The study highlights the significance of using DRLs for optimizing CT-guided biopsy procedures, revealing notable variations in radiation exposure between helical scans covering entire anatomical regions and localized biopsy acquisitions.
Subject
Electrical and Electronic Engineering,Computer Graphics and Computer-Aided Design,Computer Vision and Pattern Recognition,Radiology, Nuclear Medicine and imaging
Reference37 articles.
1. IMV Medical Information Division (2022, February 02). 2019 Global Imaging Market Outlook Report. Available online: https://imvinfo.com/product/imv-2019-global-imaging-market-outlook-report/.
2. Fluoro-Ct Guided Biopsy Of Lung Nodules: A Step By Step Revision;Branco;Port. J. Card. Thorac. Vasc. Surg.,2022
3. Zhang, L., Shi, L., Xiao, Z., Qiu, H., Peng, P., and Zhang, M. (2018). Coaxial technique-promoted diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for small and deep lung lesions. PLoS ONE, 13.
4. Augmented reality 3D navigation system for percutaneous CT-guided pulmonary ground-glass opacity biopsies: A comparison with the standard CT-guided technique;Faiella;J. Thorac. Dis.,2022
5. Radiation dose levels for interventional CT procedures;Leng;Am. J. Roentgenol.,2011