Abstract
This paper presents a method that has been developed to reduce the torque ripples under healthy and open-circuit fault-tolerant (OCFT) conditions for a multiphase permanent magnet (PM) machine. For smooth torque, both the phase current and the back electromotive force (back-EMF) should be purely sinusoidal. To improve the torque in a multiphase machine, higher-order current harmonics are injected, which are related to the harmonics in the back-EMF. For this reason, generally, multiphase machines are designed with higher-order back-EMF harmonics. However, these harmonics produce ripples in the torque. In light of this, a torque ripple cancellation method has been developed that first determines an additional current component from the harmonic content of the back-EMF and then injects these additional components to cancel the torque ripple. It has been found that this new torque ripple cancellation method works for both faultless and faulty conditions in a five-phase PM machine. The method has been validated using Finite Element Analysis, and the results are presented in this paper.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献