Abstract
A new voltametric method for highly sensitive propranolol (PROP) determination was developed. A glassy carbon electrode modified with a hybrid material made of carbon black (CB) and Nafion was used as the working electrode. The preconcentration potential and time were optimized (550 mV and 15 s), as well as the supporting electrolyte (0.1 mol L−1 H2SO4). For 15 s preconcentration time, linearity was achieved in the range 0.5–3.5 μmol L−1 and for 120 s in 0.02–0.14 μmol L−1. Based on the conducted calibration (120 s preconcentration time) limit of detection (LOD) was calculated and was equal to 7 nmol L−1. To verify the usefulness of the developed method, propranolol determination was carried out in real samples (tablets and freeze-dried urine). Recoveries were calculated and were in the range 92–102%, suggesting that the method might be considered as accurate. The repeatability of the signal expressed as relative standard deviation (RSD) was equal to 1.5% (n = 9, PROP concentration 2.5 µmol L−1). The obtained results proved that the developed method for propranolol determination might be successfully applied in routine laboratory practice.
Funder
AGH University of Science and Technology
Subject
General Materials Science
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献