Numerical Study on Minimum Shear Connection Ratio of Tie-Bars in Steel Plate–Concrete Composite Beams Subjected to Out-of-Plane Cyclic Loading
-
Published:2022-02-10
Issue:4
Volume:12
Page:1820
-
ISSN:2076-3417
-
Container-title:Applied Sciences
-
language:en
-
Short-container-title:Applied Sciences
Author:
Lu Bing,Li Cuihua,Liu Cong,Guo Lanhui
Abstract
The failure modes of tie-bars under monotonic loading and cyclic loading are ductility and brittleness, respectively. They can significantly affect the design for tie-bars in a steel plate–concrete (SC) composite structure. A 3D finite element model of a SC composite beam was developed and verified through a quasi-static test. Two rules on the interfacial shear distribution were deduced and verified. Then, a total of 188 finite element models were developed to investigate the minimum shear connection ratio of tie-bars in SC composite beams, which can ensure the sufficient energy dissipation capacity of a SC composite beam under out-of-plane cyclic loading. The influences of the shear connection ratio, shear span versus depth ratio, stiffness, and number of tie-bars on the seismic behavior of a SC composite beam were investigated. Finally, a design method for tie-bars in the SC composite beam under out-of-plane cyclic loading was proposed.
Funder
Scientific Research Fund of Institute of Engineering Mechanics, China Earthquake Administration
National Natural Science Foundation of China
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference26 articles.
1. Shell composite construction for shallow draft immersed tube tunnels;Tomlinson,1989
2. The design of double skin composite elements