Abstract
When a malfunction occurs in a marine gas turbine, its thermal efficiency will decrease slightly, and the gas path fault is often difficult to distinguish. In order to solve this problem, based on the second law of thermodynamics, the endogenous irreversible loss (EIL) model of the marine gas turbine is established, and the exergy loss analysis under normal conditions is carried out to verify the accuracy of the model. The fault diagnosis of gas turbine gas path based on EIL is proposed, and a simulation experiment conducted on a three-shaft marine gas turbine demonstrated that the proposed approach can detect and isolate gas path fault accurately under different operating conditons and enviroments.
Funder
Fundamental Research Funds for the Central Universities
National Major Science and Technology Projects of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献