The Stability of Analytes of Ionized Magnesium Concentration and Its Reference Range in Healthy Volunteers

Author:

Al-Maqbali Juhaina Salim12ORCID,Al Alawi Abdullah M.34ORCID,Al-Falahi Zubaida34,Falhammar Henrik56ORCID,Al-Zakwani Ibrahim12,Al Za’abi Mohammed1ORCID

Affiliation:

1. Department of Pharmacology and Clinical Pharmacy, College of Medicine and Health Science, Sultan Qaboos University, Muscat 123, Oman

2. Department of Pharmacy, Sultan Qaboos University Hospital, Muscat 123, Oman

3. Department of Medicine, Sultan Qaboos University Hospital, Muscat 123, Oman

4. Internal Medicine Residency Training Program, Oman Medical Specialty Board, Muscat 130, Oman

5. Department of Endocrinology, Karolinska University Hospital, 17176 Stockholm, Sweden

6. Department of Molecular Medicine and Surgery, Karolinska Institute, 17176 Stockholm, Sweden

Abstract

This study aimed to determine the stability of refrigerated analytes of iMg concentration at different time intervals and to establish iMg reference range in a cohort of healthy Omani volunteers (≥18 years). The concentrations of iMg were measured using the direct ion-selective electrode technique. Pearson’s and Lin’s concordance correlation coefficients along with the Bland–Altman plot were used to assess the levels of agreement between iMg concentrations of fresh and refrigerated blood samples at different time intervals. The study included 167 volunteers (51% females) with a median age of 21 (range: 20–25) years. The median, 2.5th, and 97.5th percentiles for fresh iMg reference ranges were 0.55, 0.47, and 0.68 mmol/L, respectively. The overall agreement between the fresh and refrigerated iMg concentrations was poor (rho-c = 0.51; p < 0.001). However, according to Altman’s definition, iMg concentrations of the refrigerated samples for a period of ≤1 h had an excellent correlation with the fresh iMg concentrations (Lin’s rho-c = 0.80), with a small average bias difference of 0.009 (95%CI; −0.025–0.043). A cut-off refrigeration period within ≤1 h at 2–8 °C can be considered an alternate time frame for the gold standard measurement (fresh or within 0.5 h).

Funder

Nova Biomedical

Nova Biomedical and Global Source Trading

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3