Research on the Quality of Partially Removable Skeletal Prostheses Made Using Classical Versus Modern Sintering Techniques

Author:

Antohe Magda-Ecaterina1,Dascălu Cristina Gena2ORCID,Forna Doriana Agop3,Hitruc Elena Gabriela4,Cimpoeșu Nicanor5,Forna Norina Consuela1

Affiliation:

1. 3rd Dental Medicine Department, Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania

2. Department of Medical Informatics, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universității Street, 700115 Iasi, Romania

3. 1st Dental Medicine Department, Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 16 Universității Street, 700115 Iasi, Romania

4. “Petru Poni” Institute of Macromolecular Chemistry, Aleea Grigore Ghica-Vodă, 41A, 700487 Iasi, Romania

5. Faculty of Materials Science and Engineering, “Gheorghe Asachi” Technical University, Bulevardul Profesor Dimitrie Mangeron 67, 700050 Iasi, Romania

Abstract

Conventional partially removable skeletal dentures are one of the most common therapeutic solutions offered to edentulous patients worldwide. The present study aims to compare the skeleton of removable dentures realized via classical techniques to that realized via modern techniques, represented by the laser sintering technique, with the comparative aspects being realized through the evaluation of atomic force microscopy (AFM). A total of 20 metal frameworks made of Co-Cr were sectioned, representing the infrastructure of partially removable skeletal dentures, developed using the classical technique versus the laser sintering technique. The infrastructures of partially removable skeletal dentures were designed for both the maxilla and the mandible, with the design of each type of denture being identical, and were developed using both techniques. The roughness values are different depending on the technological method used; for the conventional casting technique, we have higher roughness for the component elements of the partially removable skeletal denture that have more stretch, e.g., the major connector, and for the 3D laser sintering technique, lower roughness is obtained for the component elements that have a lower stretch, e.g., the clasp arms, the minor connector, or the junction between the saddles and the major connector. The clinical implications of the presence of roughness at the level of the active arms or at the level of the connector saddle junction are represented by the risk of fracture, which confers real discomfort to the patient.

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Reference50 articles.

1. A scoping review on the accuracy of fit of removable partial dentures in a developing digital context;Alzoubi;Clin. Cosmet. Investig. Dent.,2020

2. The rationale of partial Denture Choice;Applegate;J. Prosthet. Dent.,1960

3. The fit accuracy of removable partial denture metal frameworks using conventional and 3D printed techniques: An in vitro study;Bajunaid;J. Contemp. Dent. Pract.,2019

4. 3D Metal Printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant- supported prostheses;Barbin;J. Mech. Behav. Biomed. Mater.,2020

5. Clinical Performance of Cast Clasp-Retained Removable Partial Dentures: A Retrospective Study;Behr;Int. J. Prosthodont.,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3