SARS-CoV-2 Serology: Utility and Limits of Different Antigen-Based Tests through the Evaluation and the Comparison of Four Commercial Tests

Author:

Gdoura MariemORCID,Halouani Habib,Sahli Donia,Mrad MehdiORCID,Chamsa Wafa,Mabrouk Manel,Hogga Nahed,Ben-Salem KamelORCID,Triki Henda

Abstract

Introduction: SARS-CoV-2 serology have several indications. Currently, as there are various types available, it is important to master their performance in order to choose the best test for the indication. We evaluated and compared four different commercial serology tests, three of them had the Food and Drug Administration Emergency Use Authorization (FDA-EUA). Our goal was to provide new data to help guide the interpretation and the choice of the serological tests. Methods: Four commercial tests were studied: Elecsys® Roche® on Cobas® (total anti-nucleocapsid (N) antibodies), VIDAS® Biomerieux® (IgM and IgG anti- receptor binding domain (RBD) antibodies), Mindray® (IgM and IgG anti-N and anti-RBD antibodies) and Access® Beckman Coulter® (IgG anti-RBD antibodies). Two panels were tested: a positive panel (n = 72 sera) obtained from COVID-19-confirmed patients with no vaccination history and a negative panel (n = 119) of pre-pandemic sera. The analytical performances were evaluated and the ROC curve was drawn to assess the manufacturer’s cut-off for each test. Results: A large range of variability between the tests was found. The Mindray®IgG and Cobas® tests showed the best overall sensitivity, which was equal to 79.2% CI 95% (67.9–87.8). The Cobas® test showed the best sensitivity after 14 days of COVID-19 molecular confirmation; which was equal to 85.4% CI 95% (72.2–93.9). The Access® test had a lower sensitivity, even after day 14 (55.5% CI 95% (43.4–67.3)). The best specificity was noted for the Cobas®, VIDAS®IgG and Access® IgG tests (100% CI 95% (96.9–100)). The IgM tests, VIDAS®IgM and Mindray®IgM, showed the lowest specificity and sensitivity rates. Overall, only 43 out of 72 sera (59.7%) showed concordant results by all tests. Retained cut-offs for a significantly better sensitivity and accuracy, without significant change in the specificity, were: 0.87 for Vidas®IgM (p = 0.01) and 0.14 for Access® (p < 10−4). The combination of Cobas® with Vidas® IgM and IgG offered the best accuracy in comparison with all other tests combinations. Conclusion: Although using an FDA-EUA approved serology test, each laboratory should carry out its own evaluation. Tests variability may raise some concerns that seroprevalence studies may vary significantly based on the used serology test.

Funder

Tunisian Ministry of Higher Education and Scientific

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3