Choice of Polymer, but Not Mesh Structure Variation, Reduces the Risk of Bacterial Infection with Staphylococcus aureus In Vivo

Author:

Schmitz Sophia M.1ORCID,Helmedag Marius J.1ORCID,Kroh Andreas1ORCID,Heise Daniel1ORCID,Klinge Uwe1,Lambertz Andreas1,Hornef Mathias W.2,Neumann Ulf P.1,Eickhoff Roman M.1

Affiliation:

1. Department of General, Visceral and Transplantation Surgery, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074 Aachen, Germany

2. Department of Medical Microbiology, RWTH Aachen University, Pauwelsstr. 30, 52074 Aachen, Germany

Abstract

Background: Synthetic mesh material is of great importance for surgical incisional hernia repair. The physical and biochemical characteristics of the mesh influence mechanical stability and the foreign body tissue reaction. The influence on bacterial infections, however, remains ill-defined. The aim of the present study was to evaluate the influence of a modified mesh structure with variation in filament linking on the occurrence of bacterial infection that is indicated by the occurrence of CD68+, CD4+, and CD8+ cells in two different materials. Methods: A total of 56 male Sprague Dawley rats received a surgical mesh implant in a subcutaneous abdominal position. The mesh of two different polymers (polypropylene (PP) and polyvinylidenfluoride (PVDF)) and two different structures (standard structure and bold structure with higher filament linking) were compared. During the implantation, the meshes were infected with Staphylococcus (S.) aureus. After 7 and 21 days, meshes were explanted, and the early and late tissue responses to infection were histologically evaluated. Results: Overall, the inflammatory tissue response was higher at 7 days when compared to 21 days. At 7 days, PP meshes of the standard structure (PP-S) showed the strongest inflammatory tissue response in comparison to all the other groups. At 21 days, no statistically significant difference between different meshes was detected. CD8+ cytotoxic T cells showed a significant difference at 21 days but not at 7 days. PP meshes of both structures showed a higher infiltration of CD8+ T cells than PVDF meshes. CD4+ T helper cells differed at 7 days but not at 21 days, and PVDF meshes in a bold structure showed the highest CD4+ T cell count. The number of CD68+ macrophages was also significantly higher in PP meshes in a standard structure when compared to PVDF meshes at 21 days. Conclusion: The inflammatory tissue response to S. aureus infection appears to be highest during the early period after mesh implantation. PP meshes showed a higher inflammatory response than PVDF meshes. The mesh material appears to be more important for the risk of infection than the variation in filament linking.

Funder

Federal Ministry of Education and Research

Publisher

MDPI AG

Subject

General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)

Reference23 articles.

1. Mesh implants for hernia repair: An update;Klinge;Expert Rev. Med. Devices,2018

2. Mesh-related infections after hernia repair surgery;Falagas;Clin. Microbiol. Infect. Off. Publ. Eur. Soc. Clin. Microbiol. Infect. Dis.,2005

3. Risk factors for mesh-related infections after hernia repair surgery: A meta-analysis of cohort studies;Mavros;World J. Surg.,2011

4. Evaluation of new prosthetic meshes for ventral hernia repair;Burger;Surg. Endosc.,2006

5. Adhesion formation of a polyvinylidenfluoride/polypropylene mesh for intra-abdominal placement in a rodent animal model;Junge;Surg. Endosc.,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3