Abstract
Background: The development of automated seizure detection methods using EEG signals could be of great importance for the diagnosis and the monitoring of patients with epilepsy. These methods are often patient-specific and require high accuracy in detecting seizures but also very low false-positive rates. The aim of this study is to evaluate the performance of a seizure detection method using EEG signals by investigating its performance in correctly identifying seizures and in minimizing false alarms and to determine if it is generalizable to different patients. Methods: We tested the method on about two hours of preictal/ictal and about ten hours of interictal EEG recordings of one patient from the Freiburg Seizure Prediction EEG database using machine learning techniques for data mining. Then, we tested the obtained model on six other patients of the same database. Results: The method achieved very high performance in detecting seizures (close to 100% of correctly classified positive elements) with a very low false-positive rate when tested on one patient. Furthermore, the model portability or transfer analysis revealed that the method achieved good performance in one out of six patients from the same dataset. Conclusions: This result suggests a strategy to discover clusters of similar patients, for which it would be possible to train a general-purpose model for seizure detection.
Subject
General Biochemistry, Genetics and Molecular Biology,Medicine (miscellaneous)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献