Thirty-Fold Increase in Relative Sensitivity of Dy3+ Luminescent Boltzmann Thermometers Using Multiparameter and Multilevel Cascade Temperature Readings

Author:

Antić Željka1,Ćirić Aleksandar1ORCID,Sekulić Milica1ORCID,Periša Jovana1,Milićević Bojana1,Alodhayb Abdullah N.2ORCID,Alrebdi Tahani A.3ORCID,Dramićanin Miroslav D.1ORCID

Affiliation:

1. Centre of Excellence for Photoconversion, Vinča Institute of Nuclear Sciences—National Institute of the Republic of Serbia, University of Belgrade, 11001 Belgrade, Serbia

2. Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia

3. Department of Physics, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia

Abstract

The sensitivity of luminescent Boltzmann thermometers is restricted by the energy difference between the thermally coupled excitement levels of trivalent lanthanides, and their values further decrease with increases in temperature, rendering their use at high temperatures difficult. Here, we demonstrate how to overcome this sensitivity limitation by employing multiparameter and multilevel cascade temperature readings. For this purpose, we synthesized Dy3+:Y2SiO5, a phosphor whose emission is known to begin quenching at very high temperatures. Its photoluminescence-emission features, later used for thermometry, consisted of two blue emission bands centered around 486 nm and 458 nm, and two bands centered around 430 nm and 398 nm, which were only visible at elevated temperatures. Next, we performed thermometry using the standard luminescence-intensity ratio (LIR) method, which employs the 4F9/2 and 4I15/2 Dy3+ levels’ emissions and the multilevel cascade method, which additionally uses the 4G11/2 level and overlapping intensities of 4I13/2, 4M21/2, 4K17/2, and 4F7/2 levels to create two LIRs with a larger energy difference than the standard LIR. This approach yielded a sensitivity that was 3.14 times greater than the standard method. Finally, we simultaneously exploited all the LIRs in the multiparameter temperature readings and found a relative sensitivity that was 30 times greater than that of the standard approach.

Funder

NATO Science for Peace and Security Program

Ministry of Science, Technological Development and Innovation of the Republic of Serbia

Princess Nourah bint Abdulrahman University

King Saud University

Publisher

MDPI AG

Subject

Inorganic Chemistry,Condensed Matter Physics,General Materials Science,General Chemical Engineering

Reference39 articles.

1. A brief history of phosphor thermometry;Allison;Meas. Sci. Technol.,2019

2. Dramićanin, M. (2018). Luminescence Thermometry, Elsevier.

3. Quintanilla, M., Benayas, A., Naccache, R., and Vetrone, F. (2015). Thermometry at the Nanoscale, Royal Society of Chemistry.

4. Lanthanide-Based Thermometers: At the Cutting-Edge of Luminescence Thermometry;Brites;Adv. Opt. Mater.,2018

5. Non-Boltzmann Luminescence in NaYF4:Eu3+: Implications for Luminescence Thermometry;Geitenbeek;Phys. Rev. Appl.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3