Effects of Pore Size Parameters of Titanium Additively Manufactured Lattice Structures on the Osseointegration Process in Orthopedic Applications: A Comprehensive Review

Author:

Alkentar RashwanORCID,Kladovasilakis NikolaosORCID,Tzetzis DimitriosORCID,Mankovits Tamás

Abstract

Architected materials are increasingly applied in form of lattice structures to biomedical implant design for the purpose of optimizing the implant’s biomechanical properties. Since the porous design of the lattice structures affects the resulting properties of the implant, its parameters are being investigated by numerous research articles. The design-related parameters of the unit cells for a strut-architected material are mainly the pore size and the strut thickness. Until today, researchers have not been able to decide on the perfect values of the unit cell parameters for the osseointegration process and tissue regeneration. Based on in vivo and in vitro experiments conducted in the field, researchers have suggested a range of values for the parameters of the lattice structures where osseointegration is in acceptable status. The present study presents a comprehensive review of the research carried out until today, experimenting and proposing the optimum unit cell parameters to generate the most suitable lattice structure for the osseointegration procedure presented in orthopedic applications. Additional recommendations, research gaps, and instructions to improve the selection process of the unit cell parameters are also discussed.

Publisher

MDPI AG

Subject

Inorganic Chemistry,Condensed Matter Physics,General Materials Science,General Chemical Engineering

Reference107 articles.

1. Park, J.B., and Lakes, R.S. (2007). Metallic Implant Materials BT—Biomaterials, Springer.

2. Biomedical Applications of Polymer-Composite Materials: A Review;Ramakrishna;Compos. Sci. Technol.,2001

3. Anisotropy of Young’s Modulus of Bone;Katz;Nature,1980

4. Ti Based Biomaterials, the Ultimate Choice for Orthopaedic Implants—A Review;Geetha;Prog. Mater. Sci.,2009

5. On the Mechanisms of Biocompatibility;Williams;Biomaterials,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3