Urinary Artificial Sphincter in Male Stress Urinary Incontinence: Where Are We Today? A Narrative Review

Author:

Ricapito Anna12ORCID,Rubino Matteo12,Annese Pasquale2,Mancini Vito2,Falagario Ugo2,Cormio Luigi2,Carrieri Giuseppe2,Busetto Gian2ORCID,Bettocchi Carlo12

Affiliation:

1. Andrology Unit, Department of Urology and Organ Transplantation, University of Foggia, 71122 Foggia, Italy

2. Department of Urology and Organ Transplantation, University of Foggia, 71122 Foggia, Italy

Abstract

Introduction: Urinary incontinence is a prevalent condition, especially in elderly men, with stress urinary incontinence (SUI) being a common cause after radical prostatectomy. The artificial urinary sphincter (AUS), particularly the AMS 800™ device, has been the gold-standard treatment for moderate-severe male SUI for decades. Despite some technical advancements and alternative devices like ZSI-375, Victo, and BR-SL-AS 904 being introduced, there is limited literature comparing their effectiveness to the AMS 800™. Methods: This literature review compares the AMS 800™ to the newer technologies in the management of SUI. We reviewed the current literature on urinary sphincter implant in male stress incontinence, including AMS 800™, ZSI-375, Victo, and BR-SL-AS 904. Findings: The AMS 800™ is a sophisticated system consisting of an inflatable cuff, a pressure-regulating balloon, and a control pump. Studies show continence rates ranging from 61% to 100% with AMS 800™ implants, with low infection rates and significant improvement in patients’ quality of life. The ZSI-375 sphincter is a unique single-piece cuff without an abdominal reservoir, simplifying implantation. Preliminary data show a social continence rate of 73% at six months, with lower complication rates than the AMS 800™. The VICTO® device offers adjustable pressure and a stress relief mechanism, providing conditional occlusion of the urethra. Early studies report a satisfaction rate of up to 94.2% and a complication rate of 17.6%. BR-SL-AS 904 is a newly proposed urinary sphincter, but due to the limited number of cases and a single study, its efficacy and complication rates remain uncertain. Conclusions: Overall, AMS 800™ remains the gold-standard treatment for SUI after radical prostatectomy. Alternative devices like ZSI-375 and VICTO® show promising results, but longer studies and more data are needed to establish their effectiveness and safety compared with the AMS 800™. Further research and ongoing monitoring are essential to address mechanical issues associated with AUS implants.

Publisher

MDPI AG

Subject

General Chemical Engineering

Reference21 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3