Abstract
Knee rehabilitation therapy after trauma or neuromotor diseases is fundamental to restore the joint functions as best as possible, exoskeleton robots being an important resource in this context, since they optimize therapy by applying tailored forces to assist or resist movements, contributing to improved patient outcomes and treatment efficiency. One of the points that must be taken into account when using robots in rehabilitation is their interaction with the patient, which must be safe for both and guarantee the effectiveness of the treatment. Therefore, the objective of this study was to assess the interaction between humans and an exoskeleton during the execution of knee flexion–extension movements under various configurations of robot assistance and resistance. The evaluation encompassed considerations of myoelectric activity, muscle recruitment, robot torque, and performed movement. To achieve this, an experimental protocol was implemented, involving an individual wearing the exoskeleton and executing knee flexion–extension motions while seated, with the robot configured in five distinct modes: passive (P), assistance on flexion (FA), assistance on extension (EA), assistance on flexion and extension (CA), and resistance on flexion and extension (CR). Results revealed distinctive patterns of movement and muscle recruitment for each mode, highlighting the complex interplay between human and robot; for example, the largest RMS tracking errors were for the EA mode (13.72 degrees) while the smallest for the CR mode (4.47 degrees), a non-obvious result; in addition, myoelectric activity was demonstrated to be greater for the completely assisted mode than without the robot (the maximum activation levels for the vastus medialis and vastus lateralis muscles were more than double those when the user had assistance from the robot). Tracking errors, muscle activations, and torque values varied across modes, emphasizing the need for careful consideration in configuring exoskeleton assistance and resistance to ensure effective and safe rehabilitation. Understanding these human–robot interactions is essential for developing precise rehabilitation programs, optimizing treatment effectiveness, and enhancing patient safety.
Funder
Pro-Rectory of Research of University of São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES)-Finance Code 001, PGPTA
São Paulo Research Foundation
Reference21 articles.
1. Panayiotou Charalambous, C. (2022). The Knee Made Easy, Springer International Publishing.
2. Darrow, M. (2002). The Knee Sourcebook, McGraw-Hill.
3. Biomechanical considerations for rehabilitation of the knee;McGinty;Clin. Biomech.,2000
4. Brittberg, M. (2020). Lower Extremity Joint Preservation: Techniques for Treating the Hip, Knee, and Ankle, Springer.
5. Deconditioned Knee: The Effectiveness of a Rehabilitation Program that Restores Normal Knee Motion to Improve Symptoms and Function;Shelbourne;N. Am. J. Sport. Phys. Ther.,2007