Erythrocyte Folyl Polyglutamate Synthetase Activity Profiling as a Potential Tool for the Prediction of Methotrexate Efficacy and Toxicity in Rheumatoid Arthritis

Author:

Kumar Amar1,Arain Mudassar Iqbal2,Bhadbhade Pooja3,Funk Ryan12ORCID

Affiliation:

1. Center for Computational Biology, University of Kansas, Kansas City, KS 66047, USA

2. Department of Pharmacy Practice, University of Kansas, Kansas City, KS 66047-1620, USA

3. Division of Allergy, Clinical Immunology, and Rheumatology, University of Kansas Medical Center, Kansas City, KS 66160, USA

Abstract

Methotrexate (MTX) is the cornerstone of therapy in the treatment of rheumatoid arthritis (RA). However, its efficacy and toxicity are variable and remain unpredictable. Interindividual variation in the metabolism of MTX by the enzyme folyl polyglutamate synthetase (FPGS) has been associated with response variability in RA. In this work, we propose the development of a FPGS phenotyping assay that can be evaluated as a tool for the prediction of efficacy and toxicity in patients with RA prior to initiating MTX therapy. FPGS activity was measured in erythrocyte lysate by monitoring methotrexate polyglutamate (MTX + Glun) formation using ultra-performance liquid chromatography tandem–mass spectrometry (UPLC/MS/MS). Erythrocyte FPGS activity was measured in newly diagnosed RA (n = 35) and osteoarthritis (n = 7) patients. The enzymatic assay was optimized for measuring FPGS activity in 25 µL of packed erythrocytes over two hours. The coefficient of variation for intra- and inter-day analysis was found to be 5% and 12%, respectively. The method was used to measure FPGS enzyme kinetics, resulting in a mean (SD) Km of 30.3 (4.8) µM and a Vmax of 612 (193) pmol MTX + Glu2/h/mL of packed erythrocytes. Mean (SD) erythrocyte FPGS activity in patients with RA was found to be 445.93 (344.50) pmol MTX + Glu2/h/mL and with a 26-fold difference in the range (range: 83–2179 pmol MTX + Glu2/h/mL) whereas for patients with OA, it was found to be 409.80 (157.66) pmol MTX + Glu2/h/mL with a 3.5-fold difference in the range (range: 200.95–683.93 pmol MTX + Glu2/h/mL). Monitoring erythrocyte FPGS activity may be a feasible strategy of phenotyping for methotrexate efficacy and toxicity in patients with RA.

Funder

University of Kansas

NCATS

NIGMS

Publisher

MDPI AG

Subject

General Medicine

Reference80 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3