Abstract
According to the beam propagation method, a fiber refractive index-sensitive multimode interference (MMI) structure fabricated by splicing a self-made silica glass rod between two single mode fibers (SMF–NCF (no core fiber)–SMF structure) is proposed for liquid level monitoring. Theoretical and experimental investigation was carried out meticulously using a 4.5 cm and a 9.5 cm long silica glass rod. It is proved that the simple and economical sensor with the shorter length has high sensitivity, satisfactory repeatability, and favorable stability. The sensitivity climbs with the increase in refractive index of the measured liquid, which is 204 pm/mm for pure water, 265.8 pm/mm for 10% glycerin solution, and 352.5 pm/mm for 25% glycerin solution. The proposed sensor can be standardized in certain application circumstances to achieve accurate liquid level monitoring.
Funder
National Key Research and Development Program of China
National Natural Science Foundation of China
Fundamental Research Funds for the Central Universities
111 Project
Subject
Radiology Nuclear Medicine and imaging,Instrumentation,Atomic and Molecular Physics, and Optics
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献