Affiliation:
1. College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou 325035, China
Abstract
This paper presents a few-mode fiber (FMF) various fault-detection method for long-reach mode division multiplexing (MDM) based on multi-mode transmission reflection analysis (MM-TRA). By injecting unmodulated continuous light into the FMF, and measuring and quantitatively analyzing the transmitted and reflected or Rayleigh backscattering power of different spatial modes, it is possible to accurately detect and locate reflective and non-reflective fault events. This paper discusses the localization accuracy of fault types such as FMF break, FMF link connector mismatch, and FMF bending. Theoretical analysis and simulation experimental results demonstrate that the proposed MM-TRA can provide an effective characterization of various faults and can achieve high fault localization accuracy. In addition, the influence of mode crosstalk of mode multiplexer/demultiplexer and mode coupling in FMF on the localization accuracy of various faults are considered. The results indicate that when using the combination of LP01 and LP21 modes, the localization errors for the FMF break, connector mismatch, and bending are 3.42 m, 1.97 m, and 3.29 m, respectively, demonstrating good fault localization performance.
Funder
National Natural Science Foundation of China
Zhejiang Provincial Natural Science Foundation of China