Abstract
Currently, laser systems based on active elements doped with Yb3+ with simultaneously high pulse repetition rates and high peak power are in demand for many applications. High thermal load of active elements is the primary limiting factor for average power scaling. Experimental investigation of temperature distribution in active elements is of particular importance for estimation of cooling efficiency and for thermal processes’ monitoring. In the present work, the method of dynamic laser thermometry is proposed for temperature distribution investigation within cryogenically cooled Yb3+-doped active elements. The method is based on the dependence of the Yb3+ ion absorption cross-section on temperature at a wavelength of 1030 nm. The method was tested to study the 2D temperature map of the Yb:YAG active element of the high-power, diode-pumped, cryogenically cooled laser amplifier. The best measurement accuracy ±3 K is achieved at the maximal temperature 176 K. The results of numerical simulation are in good agreement with the experimental data. On the basis of the investigation, the quality of the cooling system is evaluated. The advantages and other possible applications of the method are discussed.
Funder
Russian Foundation for Basic Research
RF Ministry of Science and Higher Education
Russian Science Foundation
Subject
Radiology, Nuclear Medicine and imaging,Instrumentation,Atomic and Molecular Physics, and Optics
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献