Abstract
At the Kielce University of Technology, a concept of the accurate measurement of sphericity deviations of machine parts has been developed. The concept is based upon the measurement of roundness profiles in many clearly defined cross-sections of the workpiece. Measurements are performed with the use of a typical radius change measuring instrument equipped with a device for accurate positioning of the ball. This paper focuses on the statistical analysis of the differences between measurement results of spherical parts obtained by the new and traditional method. The differences were analyzed by applying preselected statistical parameters and diagrams. Results of the analysis revealed that that the new method may contribute to a much more reliable measurement of form deviations of spherical parts.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry