Immediate Effect of Whole-Body Vibration on Skin Temperature and Lower-Limb Blood Flow in Older Adults with Type 2 Diabetes: Pilot Study

Author:

Alves Kennedy Freitas PereiraORCID,Ferreira Ana Paula de Lima,Parente Luana Caroline de Oliveira,Rodrigues François Talles Medeiros,Marques Thais Vitorino,Antonino Gabriel Barreto,Melo Luiz Carlos de,Villela Débora Wanderley,Guerino Marcelo Renato,Leite Wagner Souza,Campos Shirley Lima,Lucena Larissa Coutinho de,Taiar RedhaORCID,Araújo Maria das Graças Rodrigues deORCID

Abstract

The purpose of this study was to evaluate the response of a single whole-body vibration (WBV) training session to peripheral skin temperature and peripheral blood flow of older adults with type 2 diabetes. A double-blind, controlled clinical trial was conducted following the Consolidated Standards of Reporting Trials (CONSORT) guidelines. A single session of WBV (24 Hz; amplitude 4 mm; vibration time 45 s, with a series of eight repetitions with recovery between repetitions of 30 s; total time of 10 min) or sham vibration on the Kikos P204 Vibrating Platform was employed. To assess skin temperature, the FLIR E40bxs thermographic camera and the ultrasonic vascular Doppler for flow velocity were used. Evaluation occurred before and after a WBV or sham intervention. The sample consisted of three men and 17 women. In the WBV group, there was a decrease in the temperature from 29.7 °C (±1.83) to 26.6 °C (±2.27), with p = 0.01. Temperature following sham decreased from 28.6 °C (±1.84) to 26.3 °C (±2.49), with p = 0.01. Regarding blood flow, there was a decrease in the analyzed arteries, especially the left posterior tibial artery, where there was a statistically significant flow reduction from 27.1 m/s (±25.36) to 20.5 m/s (±19.66), post WBV (p = 0.01). In the sham group, an increased flow velocity was observed for all the arteries analyzed, except for the left dorsal artery. Immediately following a full-body vibration session, peripheral skin temperature and lower-limb blood flow tend to decrease in diabetic patients. However, from the design of study developed, we cannot infer the maintenance of this effect in the medium and long term.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3