Is It Possible to Have Home E-Monitoring of Pulmonary Function in Our Patients with Duchenne Muscular Dystrophy in the COVID-19 Pandemic?—A One Center Pilot Study

Author:

Wasilewska ElizaORCID,Sobierajska-Rek AgnieszkaORCID,Małgorzewicz Sylwia,Soliński MateuszORCID,Szalewska Dominika,Jassem Ewa

Abstract

Background: Duchenne muscular dystrophy (DMD) is the most common, progressive, irreversible muscular dystrophy. Pulmonary function is crucial for duration of life in this disease. Currently, the European Respiratory Society is focused on digital health, seeking innovations that will be realistic for digital respiratory medicine to support professionals and patients during the COVID-19 pandemic. Aims: The aim of this study was to investigate whether it is possible to monitor pulmonary function at home using an individual electronic spirometry system in boys with Duchenne muscular dystrophy. Materials and methods: In this observational, prospective study, conducted from March 2021 to June 2021, twenty boys with DMD (aged 8–16) were enrolled. The patients were recruited from the Rare Disease Centre, University Clinical Centre, of Gdańsk, Poland. Medical history and anthropometric data were collected, and spirometry (Jaeger, Germany) was performed in all patients at the start of the study. Each patient received an electronic individual spirometer (AioCare) and was asked to perform spirometry on their own every day, morning and evening, at home for a period of 4 weeks. The number of measurements, correctness of performing measurements, forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF) were evaluated. Results: Finally, 14 out of 20 boys enrolled in the study with a mean age of 12.5 years (7 non-ambulatory) applied and received a home spirometer (AioCare). A total of 283 measurements were performed by all patients at home for 4 weeks. Half of the patients were able to perform measurements correctly. There were no significant differences between mean values of FVC, FE1, PEF between home and hospital spirometry (p > 0.05) expect PEF pv% (p < 0.00046). Patients with higher FEV1 (p = 0.0387) and lower BMI (p = 0.0494) were more likely to take home spirometer measurements. The mean general satisfaction rating of home-spirometry was 4.33/5 (SD 0.78), the mean intelligibility rating was 4.83/5 (SD 0.58). Reasons for irregular measurements were: forgetting (43%), lack of motivation (29%), difficulty (14%), lack of time (14%). Conclusion: Home electronic monitoring of pulmonary function in patients with DMD is possible to implement in daily routines at home. This protocol should be introduced as early as possible in patients 7–8 years old with good, preserved lung function. Patients accept this form of medical care but require more education about the benefits of e-monitoring. There is a need to implement a system to remind patients of the use of electronic medical devices at home, e.g., via SMS (short message service).

Funder

Medical University of Gdańsk, Poland

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3