Comparative Performance Testing of Respirator versus Surgical Mask Using a Water Droplet Spray Model

Author:

Scheepers Paul T. J.ORCID,Wertheim Heiman F. L.,van Dael MauriceORCID,Anzion Rob,Holterman Henk JanORCID,Teerenstra Steven,de Groot MartijnORCID,Voss AndreasORCID,Hopman Joost

Abstract

Background. During the SARS-CoV-2 pandemic, there was shortage of the standard respiratory protective equipment (RPE). The aim of this study was to develop a procedure to test the performance of alternative RPEs used in the care of COVID-19 patients. Methods. A laboratory-based test was developed to compare RPEs by total inward leakage (TIL). We used a crossflow nebulizer to produce a jet spray of 1–100 µm water droplets with a fluorescent marker. The RPEs were placed on a dummy head and sprayed at distances of 30 and 60 cm. The outcome was determined as the recovery of the fluorescent marker on a membrane filter placed on the mouth of the dummy head. Results. At 30 cm, a type IIR surgical mask gave a 17.7% lower TIL compared with an FFP2 respirator. At 60 cm, this difference was similar, with a 21.7% lower TIL for the surgical mask compared to the respirator. When adding a face shield, the TIL at 30 cm was further reduced by 9.5% for the respirator and 16.6% in the case of the surgical mask. Conclusions. A safe, fast and very sensitive test method was developed to assess the effectiveness of RPE by comparison under controlled conditions.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3