Application of Blue Filters Increases the Usefulness of Moreland Test in Anomaloscopic Color Vision Assessment for Blue–Green Color Range

Author:

Michalak KrzysztofORCID,Zabel JacekORCID,Olszewski JanORCID,Wojtyła-Buciora PaulinaORCID,Przekoracka-Krawczyk AnnaORCID

Abstract

The effect of blue light filters on the anomaloscopic examination was analyzed. Thirty subjects (18–43 y, 20 female, 10 male) without color vision disorders were examined in 4 filter conditions: no filter (F-0), Blue Control Hoya (F-BC), Med-1 JZO (F-Med1) and 450 Eschenbach (F-450). Both Rayleigh test (red–green axis) and Moreland test (blue–green axis) were performed. Application of F-BC filter shows negligible effect on color vision perception in both tests. Contrary to this, the application of strong F-450 filter causes significant shift in Moreland test towards tritanopy and the decrease in correlations of Moreland parameters with Rayleigh test parameters. The application of medium strong F-Med1 filter causes the slight shift in Moreland test towards the center of the Moreland scale and increases the Spearman correlations between Moreland and Rayleigh test parameters. This observation suggests that the about 15–40% reduction of blue diode intensity in the Moreland test may be beneficial in detecting mild changes in color vision perception in the blue-green axis and may improve its usefulness in evaluating the color vision perception disorders accompanying different illnesses, such as diabetes, glaucoma, neuritis optica, or cataract. The discussion concerning the modifications of Moreland test construction is also presented.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference12 articles.

1. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma;Papaconstantinou;Clin. Ophthalmol.,2009

2. Clinical Color Vision Testing and Correlation With Visual Function

3. Visual acuity and color discrimination in patients with cataracts

4. Cataract and Refractive Surgery;Kohnen,2006

5. Predictors of vision impairment in Multiple Sclerosis

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3