Abstract
Background: Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is a significant predictor of mortality and future transplantation in heart failure patients with severely reduced ejection fraction (HFrEF). The present study evaluated the differences in peak VO2 and other prognostic variables between treadmill and cycle CPETs in these patients. Methods: In this cross-over study design, thirty males with severe HFrEF underwent CPET on both a treadmill and a cycle ergometer within 2–5 days apart, and important CPET parameters between two exercise test modalities were compared. Results: Peak VO2 was 23.12% higher on the treadmill than on cycle (20.55 ± 3.3 vs. 16.69 ± 3.01, p < 0.001, respectively). Minute ventilation to carbon dioxide production (VE/VCO2) slope was not different between the two CPET modes (p = 0.32). There was a strong positive correlation between the VE/VCO2 slopes during treadmill and cycle testing (r = 0.79; p < 0.001). VE/VCO2 slope was not related to peak respiratory exchange ratio (RER) in either modality (treadmill, r = 0.13, p = 0.48; cycle, r = 0.25, p = 0.17). The RER level was significantly higher on the cycle ergometer (p < 0.001). Conclusion: Peak VO2 is higher on treadmill than on cycle ergometer in severe HFrEF patients. In addition, VE/VCO2 slope is not a modality dependent parameter and is not related to the patients’ effort during CPET.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献