Abstract
This paper presents aspects of monitoring material dust emissions from stationary emission sources (monthly dust measurements performed on cement mill stacks—mill outlet and separator outlet). Additionally, the Portland cement mill technological process (its component parts), as well as the solutions regarding the reduction of the air emissions level, following the emission limit values (VLE), established in the integrated environmental authorization (AIM) from a cement factory in Romania, were analyzed. The paper focused on analyzing the data obtained in three different years for PM10 and dust concentrations (2018–2020). For each year, the measurements have been done in 3 months, each in a different season. The average values for each year for working conditions were: 30.22 mg/m3 (2018), 27.38 mg/m3 (2019), and 27.51 mg/m3 (2020) for working conditions and for normal conditions: 34.22 mg/m3 (2018), 30.49 mg/m3 (2019), and 30.16 mg/m3 (2020). For all 3 years, the values measured in spring were higher than the other two, both for work and normal conditions.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Reference48 articles.
1. ERLIVE Platformhttps://aerlive.ro/ce-este-ica-indicele-de-calitatea-aerului/
2. Clearing the Air: A Review of the Effects of Particulate Matter Air Pollution on Human Health
3. Health Effects of Particulate Matter,2013
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献