Introduction of Deep Learning-Based Infrared Image Analysis to Marginal Reflex Distance1 Measurement Method to Simultaneously Capture Images and Compute Results: Clinical Validation Study

Author:

Song Bokeun12ORCID,Kwon Hyeokjae13ORCID,Kim Sunje1ORCID,Ha Yooseok1ORCID,Oh Sang-Ha123,Song Seung-Han123

Affiliation:

1. Department of Plastic and Reconstructive Surgery, Chungnam National University Hospital, Daejeon 35015, Republic of Korea

2. Department of Medical Science, College of Medicine, Chungnam National University, Daejeon 35015, Republic of Korea

3. Department of Plastic and Reconstructive Surgery, College of Medicine, Chungnam National University, Daejeon 35015, Republic of Korea

Abstract

Marginal reflex distance1 (MRD1) is a crucial clinical tool used to evaluate the position of the eyelid margin in relation to the cornea. Traditionally, this assessment has been conducted manually by plastic surgeons, ophthalmologists, or trained technicians. However, with the advancements in artificial intelligence (AI) technology, there is a growing interest in the development of automated systems capable of accurately measuring MRD1. In this context, we introduce novel MRD1 measurement methods based on deep learning algorithms that can simultaneously capture images and compute the results. This prospective observational study involved 154 eyes of 77 patients aged over 18 years who visited Chungnam National University Hospital between 1 January 2023 and 29 July 2023. We collected four different MRD1 datasets from patients using three distinct measurement methods, each tailored to the individual patient. The mean MRD1 values, measured through the manual method using a penlight, the deep learning method, ImageJ analysis from RGB eye images, and ImageJ analysis from IR eye images in 56 eyes of 28 patients, were 2.64 ± 1.04 mm, 2.85 ± 1.07 mm, 2.78 ± 1.08 mm, and 3.07 ± 0.95 mm, respectively. Notably, the strongest agreement was observed between MRD1_deep learning (DL) and MRD1_IR (0.822, p < 0.01). In a Bland–Altman plot, the smallest difference was observed between MRD1_DL and MRD1_IR ImageJ, with a mean difference of 0.0611 and ΔLOA (limits of agreement) of 2.5162, which was the smallest among all of the groups. In conclusion, this novel MRD1 measurement method, based on an IR camera and deep learning, demonstrates statistical significance and can be readily applied in clinical settings.

Funder

the National Research Foundation of Korea (NRF) grant funded by the Korea government

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3