Evaluation of Femoropopliteal In-Stent Restenosis Characteristics Stratified by Stent Design

Author:

Noory Elias1ORCID,Böhme Tanja1,Salm Jonas1,Beschorner Ulrich1,Endress Larissa2,Bollenbacher Roaa1,Westermann Dirk1,Zeller Thomas1

Affiliation:

1. Department of Cardiology and Angiology, University Heart Centre Campus Bad Krozingen, Faculty of Medicine, University of Freiburg, 79189 Bad Krozingen, Germany

2. Medical Faculty, Albert-Ludwigs-University Freiburg, 79110 Freiburg im Breisgau, Germany

Abstract

Purpose: To evaluate the potential differences in characteristics of femoropopliteal in-stent restenosis (ISR) stratified by stent design with a focus on the swirling flow-inducing BioMimics 3D helical centerline stent. Methods: Patients with ISR of the superficial femoral and popliteal arteries undergoing reintervention were included in this study. The primary endpoint was the angiographic localization and extent of restenosis or reocclusion with the following five different stent systems: SMART Control stent, Supera peripheral stent, GORE® VIABAHN® endoprosthesis, BioMimics 3D stent, and Zilver® PTX® stent. Results: 414 ISR lesions were analyzed, affecting 236 Supera stents, 67 BioMimics 3D stents, 48 Zilver® PTX® stents, 38 SMART Control stents, and 25 VIABAHN® endoprostheses. The mean stent diameter and length were 5.7 ± 0.77 mm and 121.4 ± 94.8 mm, respectively. ISR included 310 (74.9%) lesions with 1 stent, 89 (21.5%) lesions with 2 stents, 14 (3.4%) lesions with 3 stents, and 1 lesion (0.2%) with 4 stents. Most lesions presented as reocclusions (67.4%) rather than focal (13.3%) or diffuse restenoses (19.3%). No significant differences in ISR lesion morphology were found. By trend, BioMimics 3D stent lesion extension was more focal (16.4% versus 12.7%, p = 0.258), with the highest proportion of lesions in which only the proximal stent third was affected (9.0% versus 5.8%, p = 0.230), as compared to the average of the other four devices. The occlusion rate was the second lowest for the BioMimics 3D stent (64.2 vs. 68.0%, p = 0.316). Risk factors for restenosis or occlusion were active smoking, pre-interventional occlusion, and popliteal intervention. Conclusion: Our results suggest that the helical centerline stent design of the BioMimics 3D stent, which results in a swirling flow with increased wall shear stress, may offer protective properties over straight stent designs, including DES and endoprosthesis, regarding localization and extension of restenosis. Prospective, randomized studies are warranted.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3