Abstract
Stackable mechanism architecture has demonstrated effective gravity-balancing over entire workspaces. Adjustable balancing is required when balancing is broken due to changing the payload at the distal end of a mechanism. In this paper, adjustable balancing of the stackable mechanism for a variable payload is investigated. For this, balancing conditions for three adjustable balancing methods are suggested, and a new balancing method combining a spring and counterweight is considered as an effective means of adjustable balancing for variable payloads. The excellent performance of the system is proven through experiments. Electromyography (EMG) sensors are employed to measure the amount of energy expenditure during the drilling task. It was verified through several tests that an operator holding a drill mounted at the distal end of a stackable arm felt less energy compared to an operator holding the drill directly in free space. The developed balancing arm was successfully applied during a mastoidectomy. A 3-step warning algorithm along with a braking function was found to be effective for safe surgery.
Funder
Ministry of Education, Science and Technology
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
15 articles.