Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography

Author:

Lin Jia-Ru1,Cheng I-Hao1,Liang Yu-Syuan2,Li Jyun-Jie1,Tsai Jen-Ming1,Wang Min-Tsung1,Lin Te-Pao1,Huang Su-Lan1,Chou Ming-Chung345ORCID

Affiliation:

1. Department of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan

2. Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan

3. Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung 807, Taiwan

4. Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

5. Center for Big Data Research, Kaohsiung Medical University, Kaohsiung 807, Taiwan

Abstract

The current study aimed to investigate the relationship between body parameters and the current–time product (mAs) in chest digital radiography using a non-contact infrared thickness-measurement sensor. An anthropomorphic chest phantom was first used to understand variations in mAs over multiple positionings during chest radiography when using the automatic exposure control (AEC) technique. In a human study, 929 consecutive male subjects who underwent regular chest examinations were enrolled, and their height (H), weight (W), and body mass index (BMI) were recorded. In addition, their chest thickness (T) was measured at exhalation using a non-contact infrared sensor, and chest radiography was then performed using the AEC technique. Finally, the relationship between four body parameters (T, BMI, T*BMI, and W/H) and mAs was investigated by fitting the body parameters to mAs using three curve models. The phantom study showed that the maximum mAs was 1.76 times higher than the lowest mAs during multiple positionings in chest radiography. In the human study, all chest radiographs passed the routine quality control procedure and had an exposure index between 100 and 212. In curve fitting, the comparisons showed that W/H had a closer relationship with mAs than the other body parameters, while the first-order power model with W/H fitted to mAs performed the best and had an R-square of 0.9971. We concluded that the relationship between W/H and mAs in the first-order power model may be helpful in predicting the optimal mAs and reducing the radiation dose for chest radiography when using the AEC technique.

Funder

Kaohsiung Armed Forces General Hospital

Ministry of Science and Technology of Taiwan

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference37 articles.

1. A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography;Zhang;Pediatr. Radiol.,2013

2. Relationship between Patient Anatomical Thickness and Radiographic Exposure Factors for Selected Radiologic Examinations;Ofori;J. Health Med. Nurs.,2016

3. Impact of body part thickness on AP pelvis radiographic image quality and effective dose;Alzyoud;Radiography,2019

4. Patient-based radiographic exposure factor selection: A systematic review;Ching;J. Med. Radiat. Sci.,2014

5. Optimisation of the AP abdomen projection for larger patient body thicknesses;Gatt;Radiography,2022