Anterior Scleral Thickness and Other Dimensions in Nanophthalmos by Swept-Source Optical Coherence Tomography: A Comparative Study

Author:

Fernández-Vigo José Ignacio12ORCID,Rodríguez-Quet Olivia1ORCID,Montolío-Marzo Elena1ORCID,Burgos-Blasco Bárbara1,Kudsieh Bachar23,González-Martin-Moro Julio45,García-Feijóo Julián1

Affiliation:

1. Department of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), 28040 Madrid, Spain

2. Department of Ophthalmology, Centro Internacional de Oftalmología Avanzada, 28010 Madrid, Spain

3. Department of Ophthalmology, Hospital Puerta de Hierro-Majadahonda, 28220 Madrid, Spain

4. Department of Ophthalmology, Hospital Universitario del Henares, 28822 Madrid, Spain

5. Faculty of Medicine, Universidad Francisco de Vitoria, 28223 Madrid, Spain

Abstract

Purpose: The purpose of this study is to assess the ocular dimensions of the anterior and posterior segment, including the anterior scleral thickness (AST) in nanophthalmos compared to control eyes. Methods: A cross-sectional comparative study was carried out in two groups: 46 eyes of 28 patients with nanophthalmos, defined as axial length (AXL) < 20.5 mm, and 60 eyes of 30 controls paired by age and sex. The AST and ocular wall thickness (OWT) were measured by optical coherence tomography in the temporal and nasal quadrants at 1, 2, and 3 mm from the scleral spur. Also, the anterior chamber depth (ACD), white-to-white (WTW), lens thickness (LT), subfoveal choroidal thickness (SFCT), and retinal thickness (RT) were evaluated. Results: The mean AXL was 19.3 ± 1.5 mm in the nanophthalmos group and 23.9 ± 1.1 mm in the control group (p < 0.001). The OWT was thicker in all measurement points in nanophthalmos (p < 0.001). There were no differences in the AST measurements between groups, except for the AST1 and the AST3 in the nasal quadrant. ACD was shallower and LT was thicker in nanophthalmos, with WTW being larger in controls (p < 0.001). SFCT and RT were thicker in nanophthalmos compared to healthy individuals (p < 0.001). Conclusions: Significant anatomical differences are found in nanophthalmic eyes. They present a shallower ACD; thicker LT, OWT, choroid, and retina; and smaller WTW diameter—although no relevant differences in the AST were observed.

Publisher

MDPI AG

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3