Bone Lengthening with a Motorized Intramedullary Nail in 34 Patients with Posttraumatic Limb Length Discrepancies

Author:

Teulières Maxime,Langlais TristanORCID,de Gauzy Jérôme Sales,Rölfing Jan DuedalORCID,Accadbled Franck

Abstract

The Fitbone® motorized nail system has been used to correct limb length discrepancies (LLD) for several years. This study focuses on its application in posttraumatic limb lengthening surgery, its outcome and challenges. Materials and methods: A prospective, single center study was conducted between 2010 and 2019 in patients treated with motorized lengthening nails. The inclusion criteria were symptomatic LLD of 20 mm or more. An imaging analysis was done using TraumaCad® software (Brainlab AG, Munich, Germany) to compare frontal alignment angles and limb length discrepancy (LLD) on preoperative and latest follow-up radiographs of the lower limbs. Results: Thirty-four patients were included with a mean age of 28.8 ± 9.7 years, a mean follow-up of 27.8 ± 13 months and a mean hospital stay of 4.4 ± 1.7 days. The mean LLD was 44 ± 18 mm in 29 femoral and 32 ± 8 mm in 4 tibial cases, which was reduced to less than 10 mm in 25/34 (74%) patients. The mean healing index was 84.6 ± 62.5 days/cm for femurs and 92 ± 38.6 days/cm for tibias. The mean time to resume full weight-bearing without walking aids was 226 days ± 133. There was no significant difference between preoperative and final follow-up alignment angles and range of motion. The mechanical lateral distal femoral angle (mLDFA) was corrected in the subgroup of 10 LLD patients with varus deformity of the femur (preoperative 95.7° (±5.0) vs. postoperative 91.5° (±3.4), p = 0.008). According to Paley’s classification, there were 14 problems, 10 obstacles and 2 complications. Discussion: Six instances of locking screw pull out, often requiring reoperation, raise the question of whether a more systematic use of blocking screws that provide greater stability might be indicated. Lack of compliance can lead to poor outcomes, patient selection in posttraumatic LLD patients is therefore important. Conclusion: Limb lengthening with a motorized lengthening nail for posttraumatic LLD is a relatively safe and reliable procedure. Full patient compliance is crucial. In-depth knowledge of lengthening and deformity correction techniques is essential to prevent and manage complications.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3