Comparison of PDMS and NOA Microfluidic Chips: Deformation, Roughness, Hydrophilicity and Flow Performance

Author:

Turcitu Tatiana1,Armstrong Curtis J. K.1,Lee-Yow Niko1ORCID,Salame Maya1ORCID,Le Andy Vinh1ORCID,Fenech Marianne1ORCID

Affiliation:

1. Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada

Abstract

Microfluidic devices are frequently manufactured with polydimethylsiloxane (PDMS) due to its affordability, transparency, and simplicity. However, high-pressure flow through PDMS microfluidic channels lead to an increase in channel size due to the compliance of the material. As a result, longer response times are required to reach steady flow rates, which increases the overall time required to complete experiments when using a syringe pump. Due to its excellent optical properties and increased rigidity, Norland Optical Adhesive (NOA) has been proposed as a promising material candidate for microfluidic fabrication. This study compares the compliance and deformation properties of three different characteristic sized (width of parallel channels: 100, 40 and 20 µm) microfluidic devices made of PDMS and NOA. The comparison of the microfluidics devices is made based on the Young’s modulus, roughness, contact angle, channel width deformation, flow resistance and compliance. The experimental resistance is estimated through the measurement of the flow at a given pressure and a precision flow meter. The characteristic time of the system is extracted by fitting the two-element resistance-compliance (RC) hydraulic circuit model. The compliance of the microfluidics chips is estimated through the measurement of the characteristic time required for channels to achieve an output flow rate equivalent to that of the input flow rate using a syringe pump and a precision flow meter. The Young modulus was found to be 2 MPa for the PDMS and 1743 MPa for the NOA 63. The surface roughness was found to be higher for the NOA 63 than for the PDMS. The hydrophilicities of materials were found comparable with and without plasma treatment. The results show that NOA devices have lower compliance and deformation than PDMS devices.

Funder

National Science and Engineering Research Council of Canada

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3